Effect of power quality on the design of proton exchange membrane water electrolysis systems

Koponen, Joonas; Ruuskanen, Vesa; Hehemann, Michael; Rauls, Edward; Kosonen, Antti; Ahola, Jero; Stolten, Detlef (2020-09-29)

Katso/Avaa
koponen_et_al_effect_of_finaldraft.pdf (1.056Mb)
Lataukset: 


Post-print / Final draft

Koponen, Joonas
Ruuskanen, Vesa
Hehemann, Michael
Rauls, Edward
Kosonen, Antti
Ahola, Jero
Stolten, Detlef
29.09.2020

Applied Energy

279

Elsevier

School of Energy Systems

https://doi.org/10.1016/j.apenergy.2020.115791
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2020111390102

Tiivistelmä

Water electrolyzer technologies may play a key role in the decarbonization of the fossil-fueled world economy. Electrolytic hydrogen production could bridge emission-free power generation and various energy end-use sectors to drive the energy system towards a net zero-emission level. In order to reduce the economic cost of the required energy transition, both the overall system efficiency in converting electrical energy into the chemical energy carried by hydrogen, and the material used to build electrolytic cell stacks, should be optimal. The effect of power quality on the specific energy consumption of proton exchange membrane (PEM) water electrolyzers is investigated with a semi-empirical cell model. An experimentally-defined polarization curve is applied to analyze cell-specific energy consumption as a function of time in the case of sinusoidal current ripples and ripples excited by an industrial 12-pulse thyristor bridge. The results show that the effective electrolyzer cell area should be up to five times as high as an ideal DC power supply when powered by the 12-pulse thyristor rectifier supply to match the specific energy consumption between the two power supply configurations. Therefore, the improvement of power quality is crucial for industrial PEM water electrolyzer systems. The presented approach is applicable to simulate the effect of power quality for different proton exchange membrane electolyzers.

Lähdeviite

Koponen, J., Ruuskanen, V., Hehemann, M., Rauls, E., Kosonen, A., Ahola, J., Stolten, D. (2020). Effect of power quality on the design of proton exchange membrane water electrolysis systems. Applied Energy, vol. 279. DOI: 10.1016/j.apenergy.2020.115791

Kokoelmat
  • Tieteelliset julkaisut [1131]
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetKoulutusohjelmaAvainsanatSyöttöajatYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste