Technical feasibility evaluation of a solar PV based off-grid domestic energy system with battery and hydrogen energy storage in northern climates

Puranen, Pietari; Kosonen, Antti; Ahola, Jero (2020-12-10)

Katso/Avaa
puranen_et_al_technical_feasibility_evaluation_post-print.pdf (2.031Mb)
Lataukset: 


Post-print / Final draft

Puranen, Pietari
Kosonen, Antti
Ahola, Jero
10.12.2020

Solar Energy

213

246-259

Elsevier

School of Energy Systems

https://doi.org/10.1016/j.solener.2020.10.089
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe20201211100333

Tiivistelmä

Self-sustaining off-grid energy systems may require both short-term and seasonal energy storage for year-around operation, especially in northern climates where the intermittency in both solar irradiation and energy consumption throughout the year is extreme. This paper examines the technical feasibility of an off-grid energy system with short-term battery storage and seasonal hydrogen storage, comprising a water electrolyzer and a fuel cell. The study is based on data from a currently grid-connected residential single-family house in Finland with an existing 21 kWp photovoltaic (PV) installation and a ground source heat pump based heating system. Energy system performance is simulated using real PV power generation data as well as data on grid electricity import and export from the house over a three-year period to find the minimum combination of battery and hydrogen storage system capacities capable of year-round off-grid operation. It is concluded that technically feasible solutions are available for the proposed setup. The most significant factor affecting the system dimensioning is found to be high peak electric power demand during times of low PV power generation, indicating a need for smart power control. Demand for battery storage capacity is found to be significant only to about 20 kWh. Fuel cell and electrolyzer nominal powers of at least 4 kW and 5 kW to 7 kW, respectively, were found to be sufficient for off-grid operation with the studied system. The storage capacity demand for 170 kg to 190 kg of hydrogen annually is, however, impractically large for residential houses.

Lähdeviite

Puranen, Pietari; Kosonen, Antti; Ahola, Jero. (2021). Technical feasibility evaluation of a solar PV based off-grid domestic energy system with battery and hydrogen energy storage in northern climates. Solar Energy, 213 p. 246–259. DOI: 10.1016/j.solener.2020.10.089

Alkuperäinen verkko-osoite

https://www.sciencedirect.com/science/article/pii/S0038092X20311592?via%3Dihub
Kokoelmat
  • Tieteelliset julkaisut [1210]
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetKoulutusohjelmaAvainsanatSyöttöajatYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste