Active Magnetic Bearing (AMB) systems are common in high-speed rotating machinery. Bearing control system input is the relative displacement data measured between the sensor and the measurement surface. In case of frame resonance, controller may create a feedback loop which may amplify the frame vibration modes. The frame vibration dynamics of 1 MW steam generator with AMB-support is studied. Vibration mode identification using FE-based model are discussed. Model-order reduction techniques are utilized to solve a large-scale numerical problem. The paper shows an update procedure for a computationally efficient reduced-order model that can be used for identifying measured unclear vibration modes.
Lähdeviite
E. Sikanen, J. Heikkinen, T. Sillanpää, E. Scherman, J. Sopanen. (2020). Identification of frame dynamics of vertically oriented high-speed steam generator using model update procedure for reduced-order model. 12th International Conference on Vibrations in Rotating Machinery : Proceedings of the 12th virtual Conference on Vibrations in Rotating Machinery XII (VIRM 12, 14-15 October 2020). CRC Press. DOI: 10.1201/9781003132639-38