An infiltration load calculation model of large-space buildings based on the grand canonical ensemble theory

Lin, Xiaojie; Zhang, Junwei; Du-Ikonen, Liuliu; Zhong, Wei (2023-04-05)

Katso/Avaa
lin_et_al_an_infiltration_final_draft.pdf (2.334Mb)
Lataukset: 


Post-print / Final draft

Lin, Xiaojie
Zhang, Junwei
Du-Ikonen, Liuliu
Zhong, Wei
05.04.2023

Energy

275

Elsevier

School of Energy Systems

https://doi.org/10.1016/j.energy.2023.127331
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2023050440833

Tiivistelmä

Air infiltration significantly impacts building energy consumption and the indoor thermal environment. The proportion of infiltration load in large-space buildings is higher than in normal buildings. Due to the particularity of building structure and function, the existing building infiltration load calculation methods are unsuitable for large-space buildings. This paper proposed a new method for analyzing the building infiltration process from a thermodynamic perspective, enabling large-space buildings' infiltration load to be calculated more accurately and quickly. Compared with the existing method, it was found that a fixed proportional difference existed, and the proposed method relied on certain assumptions. The correction factor η was introduced to correct these limitations. The proposed method was verified to be accurate and universal in actual buildings. The paper also presents the results of η in different building scenarios and discusses the influence of mechanical ventilation and ideal gas assumption on η. Compared with the air change method and the gap method, the correction factor is stable in the range of 0.257–0.278 and 0.327–0.353, respectively. Furthermore, the correction factor for a monatomic ideal gas is 40% higher than that for a diatomic ideal gas. The new method provides a more accurate and efficient way to calculate the infiltration load, which can help improve the energy efficiency of buildings and the indoor thermal environment.

Lähdeviite

Lin, X., Zhang, J., Du-Ikonen, L,, Zhong, W. (2023). An infiltration load calculation model of large-space buildings based on the grand canonical ensemble theory. Energy, vol. 275. DOI: 10.1016/j.energy.2023.127331

Kokoelmat
  • Tieteelliset julkaisut [1738]
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetKoulutusohjelmaAvainsanatSyöttöajatYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste