Frequency and amplitude of flashing-induced instability in an open natural circulation loop

Dené, Paul; Montout, Michael; Garcia, Eric; Telkkä, Joonas; Riikonen, Vesa; David, Franck (2024-05-07)

Katso/Avaa
dené_et_al_frequency_and_aam.pdf (2.476Mb)
Huom!
Sisältö avataan julkiseksi
: 08.05.2026

Post-print / Final draft

Dené, Paul
Montout, Michael
Garcia, Eric
Telkkä, Joonas
Riikonen, Vesa
David, Franck
07.05.2024

Nuclear Engineering and Design

424

Elsevier

School of Energy Systems

https://doi.org/10.1016/j.nucengdes.2024.113279
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe2024081565152

Tiivistelmä

Several nuclear reactor designs rely on passive containment cooling systems. The so-called containment wall condenser relies on natural circulation loops to extract heat from high-temperature steam in the containment to a water tank at ambient pressure. In such passive systems, phase changes can happen and cause flow instabilities in the cooling loop. The flashing-induced instability occurs when the heated fluid in the riser suddenly vaporizes due to a hydrostatic pressure decrease. This instability causes periodic flow peaks, which are of major concern but whose characteristics have not been studied quantitatively.

This paper presents two analytical models that predict the flashing frequency and a maximum flow amplitude from geometry and basic operating parameters such as power level and reservoir temperature. The expressions are derived from a physical analysis and do not involve any calibration constants. The flashing frequency appears to be driven by the power level, the inlet temperature and the riser pipe geometry. For the amplitude, the maximum flow rate can be expressed in a Froude number that depends only on the total pressure losses. These models are validated against PASI experiments and system-scale simulations with the CATHARE 3 code, both performed as part of the European Commission funded PASTELS project. Additional data from numerous experimental studies in the literature are used to extend the validity range of the frequency model.

Successfully validated against experimental data and additional simulations, these models provide an explicit relationship between oscillations characteristics and design parameters, making them valuable tools for nuclear engineers.

Lähdeviite

Dené, P., Montout, M., Garcia, E., Telkkä, J., Riikonen, V., David, F. (2024). Frequency and amplitude of flashing-induced instability in an open natural circulation loop. Nuclear Engineering and Design, vol. 424. DOI: 10.1016/j.nucengdes.2024.113279

Kokoelmat
  • Tieteelliset julkaisut [1707]
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetKoulutusohjelmaAvainsanatSyöttöajatYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste