Thermal performance and mechanism of PCM-integrated cross-flow microchannel cold plates
Ding, Xiaotong; Wang, Yu; Jamil, Kainaat; Yuan, Xiaolei (2026-07-05)
Huom!
Sisältö avataan julkiseksi: 06.07.2028
Sisältö avataan julkiseksi: 06.07.2028
Post-print / Final draft
Ding, Xiaotong
Wang, Yu
Jamil, Kainaat
Yuan, Xiaolei
05.07.2026
Applied Thermal Engineering
303
Elsevier
School of Energy Systems
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe20260812116618
https://urn.fi/URN:NBN:fi-fe20260812116618
Tiivistelmä
Efficient thermal management of high heat flux energy storage systems remains challenging because maintaining temperature uniformity under transient thermal loads is difficult. To address this issue, a phase-change-material (PCM)-integrated cross-flow microchannel cold plate is proposed that combines active liquid cooling with passive thermal energy storage to achieve synergistic thermal management. An experimentally validated three-dimensional numerical model is employed to systematically investigate the effects of PCM type (RT31, RT35, and RT42), PCM thickness (3 and 5 mm), and heat generation power (3–4 kW) on the thermal and hydraulic performance of the proposed system. Results show that PCM integration reduces the heat-source surface temperature by 3–5 °C and significantly enhances thermal uniformity. Among the tested PCMs, RT31 exhibits optimal performance because its melting temperature closely matches the operating conditions. While PCM thickness has a limited impact on steady-state temperature, it affects the transient thermal response. The introduction of PCM alters the thermal boundary condition from constant-heat-flux to near-isothermal conditions, reducing the wall-to-fluid temperature difference and leading to an apparent increase in the effective convective heat transfer coefficient of up to 132%. This increase primarily arises from the modified thermal boundary condition and the resulting reduction in temperature driving force, although a genuine contribution from enhanced fluid-side convection is also observed. Based on full-factorial experimental data, a generalized Nusselt number (Nu) correlation was developed by incorporating the Stefan number and PCM thickness ratio. The proposed correlation achieves an R2 value of 0.971 and shows a maximum deviation of 8.2% when compared with literature data. The proposed model provides a predictive framework for evaluating heat transfer performance in PCM-integrated cooling systems and offers insights into underlying heat transfer mechanisms.
Lähdeviite
Ding, X., Wang, Y., Jamil, K., Yuan, X. (2026). Thermal performance and mechanism of PCM-integrated cross-flow microchannel cold plates. Applied Thermal Engineering, vol. 303. DOI: 10.1016/j.applthermaleng.2026.132226
Alkuperäinen verkko-osoite
https://www.sciencedirect.com/science/article/abs/pii/S1359431126025342?via%3DihubKokoelmat
- Tieteelliset julkaisut [1894]