Effect of Dynamic Backplate-to-Conductor Biasing on Dendritic Corrosion in Power Module Corrosive Gas Testing

Rautio, Juuso; Leppänen, Juuli; Kärkkäinen, Tommi; Ingman, Jonny; Liu, Shenyi; Kovanen, Hilma (2026-09-09)

Katso/Avaa
rautio_et_al_effect_of_published_version.pdf (2.758Mb)
Lataukset: 


Publishers version

Rautio, Juuso
Leppänen, Juuli
Kärkkäinen, Tommi
Ingman, Jonny
Liu, Shenyi
Kovanen, Hilma
09.09.2026

IET Power Electronics

IET

School of Energy Systems

https://doi.org/10.1049/pel2.70312Digital Object Identifier (DOI)
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe20260910124332

Tiivistelmä

Corrosive gas tests are commonly used to study dendritic corrosion growth in the isolation trenches of power semiconductor modules. However, conventional tests typically apply static DC bias conditions and therefore do not reproduce the time-varying backplate-referenced electric-field components present in frequency converter operation, where the module backplate is commonly coupled to protective earth through the heat sink. In this paper, a square-wave bias voltage was applied to the backplates of standard alumina substrate power modules during mixed flowing gas exposure to study the effect of a time-varying electric field between the backplate and the top-side conductors on dendrite growth. The dynamic backplate bias was found to modify dendrite morphology in DC-biased trenches and to promote dendritic growth in trenches without an externally applied top-side conductor DC bias. The results indicate that converter-operation-related backplate-referenced field components can affect corrosion growth mechanisms and should be considered when developing field-representative corrosive gas tests for power semiconductor modules.

Lähdeviite

Rautio Juuso, Leppänen Juuli, Kärkkäinen Tommi, Ingman Jonny, Liu Shenyi, Kovanen Hilma. (2026). Effect of Dynamic Backplate-to-Conductor Biasing on Dendritic Corrosion in Power Module Corrosive Gas Testing. IET Power Electronics. DOI: 10.1049/pel2.70312

Kokoelmat
  • Tieteelliset julkaisut [1956]
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetKoulutusohjelmaAvainsanatSyöttöajatYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste