Hyppää sisältöön
    • Suomeksi
    • På svenska
    • In English
  • Suomeksi
  • In English
  • Kirjaudu
Näytä aineisto 
  •   Etusivu
  • LUTPub
  • Diplomityöt ja Pro gradu -tutkielmat
  • Näytä aineisto
  •   Etusivu
  • LUTPub
  • Diplomityöt ja Pro gradu -tutkielmat
  • Näytä aineisto
JavaScript is disabled for your browser. Some features of this site may not work without it.

Validation of the GOBLIN thermal-hydraulic system code against FIX-II LOCA experiments

Garba, Keziah (2026)

Katso/Avaa
Mastersthesis_Garba_Keziah.pdf (2.675Mb)
Huom!
Sisältö avataan julkiseksi
: 10.09.2028

Diplomityö

Garba, Keziah
2026

School of Energy Systems, Energiatekniikka

Kaikki oikeudet pidätetään.
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:NBN:fi-fe20260917126520

Tiivistelmä

This thesis presents the validation of GOBLIN, a thermal-hydraulics system code, using measurements from the FIX-II loss-of-coolant accident (LOCA) integral tests. The purpose of this work is to support the development of the methodology for licensing the new boiling water reactor (BWR) fuel design, TRITON11®. Three LOCA break sizes were simulated, specifically an intermediate-break, a large-break, and a guillotine-break.

The FIX-II facility was designed to analyse the blowdown phase of a LOCA. The facility was modelled after the Oskarshamn 2 BWR and consisted of 36 electrically heated rods. In the geometrical modelling of the facility in GOBLIN, the rods were modelled as a single bundle given the nominally identical design of each rod. The initial and boundary conditions of each experiment were then applied to simulate the transients. GOBLIN calculations of system pressure, break mass flow rate, and rod cladding temperatures at six axial levels in the core were compared with experimental data to assess the code’s predictive capability.

Good agreement was obtained for system pressure and break mass flow rate across all three tests. At the mid and top axial levels, GOBLIN generally predicted cladding temperatures to be within the experimental measurement spread. Agreement with individual rod temperatures decreased with increasing break size because the bundle-average formulation of the rods could not resolve the increasingly non-uniform thermal-hydraulic rod-to-rod variations produced during blowdown. Where non-conservative predictions occurred, they were physically explained and interpreted within the limitations of the modelling approach.

The results show that GOBLIN reproduces the global thermal-hydraulic response during the blowdown phase of BWR LOCA transients and maintains representative predictions of the bundle thermal response. The results support the continued application of GOBLIN within the TRITON11 LOCA licensing methodology, with the identified modelling limitations recognised at the methodology level for treatment.
Kokoelmat
  • Diplomityöt ja Pro gradu -tutkielmat [15768]
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetKoulutusohjelmaAvainsanatSyöttöajatYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste