Hyppää sisältöön
    • Suomeksi
    • På svenska
    • In English
  • Suomeksi
  • In English
  • Kirjaudu
Näytä aineisto 
  •   Etusivu
  • LUTPub
  • Väitöskirjat
  • Näytä aineisto
  •   Etusivu
  • LUTPub
  • Väitöskirjat
  • Näytä aineisto
JavaScript is disabled for your browser. Some features of this site may not work without it.

Energy efficiency of scaled-up alkaline water electrolyzers with a large number of series-connected cells for green hydrogen production

Hysa, Galdi (2026-11-18)

Katso/Avaa
Dissertation_Hysa_Galdi.pdf (4.099Mb)
Lataukset: 


Väitöskirja

Hysa, Galdi
18.11.2026
Lappeenranta-Lahti University of Technology LUT

Acta Universitatis Lappeenrantaensis

School of Energy Systems

School of Energy Systems, Sähkötekniikka

Kaikki oikeudet pidätetään.
Näytä kaikki kuvailutiedot
Julkaisun pysyvä osoite on
https://urn.fi/URN:ISBN:978-952-412-559-8

Kuvaus

ei tietoa saavutettavuudesta

Tiivistelmä

The increasing interest in green hydrogen as a key enabler of decarbonized energy systems has driven advancements in electrolyzer technologies powered by renewable energy. Industrial-scale electrolyzers operate at high DC currents in the kiloampere range and voltages of a few hundred volts, making power converters critical components in terms of both performance and cost. This study investigates the benefits and challenges of operating at higher voltages than those of conventional ranges (200 V–300 V) in a large-scale alkaline water electrolyzer (AWE). Higher operating voltages (1000 V–1500 V), achieved by increasing the number of series-connected cells, offer the potential to reduce capital costs and improve the energy efficiency of AC–DC converters.

In this study, three industrial rectifier topologies are analyzed and compared in terms of efficiency and cost using MATLAB/Simulink models. The investigated converters include a 6-pulse thyristor rectifier, a 12-pulse thyristor rectifier, and an IGBT-based buck rectifier. The IGBT-based buck rectifier provides significantly lower current ripple than thyristor rectifiers. However, its higher switching frequency and larger number of semiconductor devices result in increased total power losses. Furthermore, all studied AC-DC converters demonstrate reduced specific energy consumption (SEC) under higher-voltage operating conditions.

A key limitation in scaling up AWE stacks by increasing the number of series-connected cells is the presence of shunt currents, which reduces energy efficiency, particularly under partial-load conditions. To address this, an equivalent circuit model of an AWE stack was developed and verified against measurement data from an industrial-scale electrolyzer. The model incorporates detailed resistance networks representing individual cells, fluid port and manifold geometries, and gas bubble effects in the outlet channels. The analysis evaluates how increasing stack length and fluid port resistances influence shunt currents.

Furthermore, the study explores the scalability of AWEs through the concept of series-connected substacks. Both isolated and shared electrolyte circulation configurations are modeled and compared in terms of shunt currents and SEC. The findings demonstrate that dividing long stacks into shorter substacks significantly mitigates shunt currents and enables higher-voltage operation. However, practical implementation requires careful consideration of current efficiency, pressure drops in the electrolyte circulation, and overall capital cost.

In summary, this work highlights that increasing the operating voltage level of an AWE, combined with optimized stack design, can substantially enhance the energy efficiency and cost-effectiveness of green hydrogen production.
Kokoelmat
  • Väitöskirjat [1244]
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste
 

 

Tämä kokoelma

JulkaisuajatTekijätNimekkeetKoulutusohjelmaAvainsanatSyöttöajatYhteisöt ja kokoelmat

Omat tiedot

Kirjaudu sisäänRekisteröidy
LUT-yliopisto
PL 20
53851 Lappeenranta
Ota yhteyttä | Tietosuoja | Saavutettavuusseloste